(S3010) NEWBORN HAL - WIRELESS AND TETHERLESS, NEONATE AT 40-WEEKS GESTATIONAL AGE
Newborn HAL® allows you to take advanced simulation where you need to go and that can be at an accident scene, in an ER, in a Labor and Delivery room, or in a NICU. “Care in motion” also provides the opportunity for you to measure how well patient “hand-offs” take place....Read More
Category: Gaumard
Tag: jayakelana,gaumard
- Jl. Ciputat Raya No 7-8, Tanah Kusir, Kebayoran Lama Selatan, Jakarta Selatan
- (+62-21) 7265209 / 7265210
- +62 812-8531-9761
- jka92@hotmail.com
- Mon - Fri 08:30 – 17:00
General
• Available in ethnic skin tones
• Tetherless and fully responsive even while being transported
• Powered from an internal rechargeable battery or wall outlet
• Battery capable of 300 recharges and operate the simulator up to 4 hours
• Simulator receives commands from a wireless tablet PC and operate at distances up to 300 Ft. (100 m)
• Option to operate automatically using Automatic mode or by the Instructor
• Training Guide with both basic and advanced interactive scenarios
• Use pre programmed scenarios, modify them or create your own quickly and easily
• Installation and training worldwide
• Simulation Made Easy™
Airway
• Multiple upper airway sounds synchronized with breathing
• Nasal or oral intubation
• Right mainstem intubation
• Sensors detect depth of intubation
• Airway may be obstructed
• Block right lung, left lung, or both lungs
• Head tilt/ chin lift
• Jaw thrust
• Simulated suctioning techniques can be practiced
• Bag-Valve-Mask Ventilation
• Placement of conventional airway adjuncts
• Endotracheal intubation using conventional ETTs
• Sellick maneuver brings vocal cords into view
Circulation
• Measure blood pressure by palpation or auscultation
• Use real modified BP cuff to measure blood pressure
• Korotkoff sounds audible between systolic and diastolic pressures
• Pulse sites synchronized with BP and heart rate
• Bilateral IV arms with fill/drain sites
• Realistic flashback
• SubQ and IM injection sites
• Intraosseous access at tibia
• Chest compressions are measured and logged
• ECG monitoring using real devices; apply real electrodes to conductive skin regions
• Multiple heart sounds, rates and intensities
• ECG rhythms are generated in real time
• Heart sounds synchronized with ECG
• Dynamic rather than static 12 lead ECG display with optional Automatic Mode and Vital Signs Monitor
• Fontanelle, umbilical and bilateral brachial pulses synchronized with ECG
Breathing
• Control rate and depth of respiration and observe chest rise
• Automatic chest rise is synchronized with respiratory patterns
• Select independent left and right upper lung sounds
• Chest rise and lung sounds are synchronized with selectable breathing patterns
• Accommodates assisted ventilation including BVM and mechanical support
• Ventilations are measured and logged
• Chest compressions generate palpable blood pressure wave form and ECG artifacts
• Detection and logging of ventilations and compressions
• Simulated spontaneous breathing
• Variable respiratory rates and inspiratory/expiratory ratios
• Bilateral chest rise and fall
• Unilateral chest rise simulates pneumothoraces
• Normal and abnormal breath sounds
Cardiac
• ECGs are generated in real time with physiologic variations never repeating textbook patterns
• Heart sounds may be auscultated and are synchronized with ECG
Speech
• Pre recorded crying
• Articulation and Movement
• Seizure/convulsions
• Muscle tone active, right arm only, left arm only, reduced and limp
• Realistic rotation of the shoulder and hip joints
• Legs bend at the knees
• Supine or semi-recumbent positions
Other
• Central cyanosis
• Color and vital signs respond to hypoxic events and interventions
• Fill bladder and perform Foley catheterization
• Interchangeable genitalia
• Umbilical catheterization
• Umbilicus with two arteries and one vein. Even practice cutdowns
• Temperature probe placement
• Insert feeding tubes
• Auscultate bowel sounds
• Remains fully functional even while in transit User Interface
• Sensors track student actions
• Changes in condition and care provided are time stamped and logged
• View the actions of up to 6 care providers using a responsive menu or write narrative
• Generate and share diagnostic lab results
• File sharing through Vital Signs Monitor
• Links with optional recording and debriefing system integrating the event log with cameras and patient monitor
• Supplied with wireless tablet PC
• Optional automatic mode
• 20 pre programmed scenarios which can be modified by the instructor even during the scenario
• Create your own scenarios - add/edit
• Change simulator’s condition during the scenario